3. Coating Solutions For New Energy Vehicles


3.1 Coating solutions for new energy vehicles

Waterborne electrophoresis primer + waterborne amino paint + waterborne amino varnish

Product features

High gloss, high vividness, excellent flexibility, excellent water resistance, excellent chemical resistance, excellent heat resistance, excellent salt spray resistance, excellent weather resistance.

Construction guidance

The construction site should be well ventilated. If the construction is carried out in a relatively closed place, effective auxiliary facilities, such as industrial fans and fans, should be adopted to strengthen the air circulation in the construction site.

The ambient temperature shall not be less than 5℃, and the surface temperature of the substrate shall be more than 3℃ higher than the dew point temperature

The relative humidity should be less than 80%. If it is continuously cloudy and the relative humidity exceeds 80%, it is recommended to stop construction or use auxiliary ventilation equipment to enhance air circulation and ensure normal dryness.

Do not work outdoors in rain, snow or dew. If the component has been constructed and the paint film is not dry, the method of tarpaulin shielding should be adopted to protect the paint film, or the component will be moved to indoor protection.

3.2 Medium and large bus coating solution

Medium and large bus supporting system

Waterborne two-component epoxy primer + elastic putty + waterborne two-component polyurethane intermediate paint + waterborne two-component polyurethane topcoat

Product features

High gloss, high fullness, excellent flexibility, excellent adhesion, excellent rock resistance, excellent water resistance, excellent chemical resistance, excellent weather resistance.

Construction guidance

The construction site should be well ventilated. If the construction is carried out in a relatively closed place, effective auxiliary facilities, such as industrial fans and fans, should be adopted to strengthen the air circulation in the construction site.

The ambient temperature shall not be less than 5℃, and the surface temperature of the substrate shall be more than 3℃ higher than the dew point temperature

The relative humidity should be less than 80%. If it is continuously cloudy and the relative humidity exceeds 80%, it is recommended to stop construction or use auxiliary ventilation equipment to enhance air circulation and ensure normal dryness.

Do not work outdoors in rain, snow or dew. If the component has been constructed and the paint film is not dry, the method of tarpaulin shielding should be adopted to protect the paint film, or the component will be moved to indoor protection.

3.3 Coating solutions for special vehicles/trailers

Special vehicle/trailer supporting system

Waterborne two component epoxy primer + waterborne acrylic polyurethane topcoat

Product features

Primer: fast drying, good salt spray resistance, excellent adhesion

Finish: high gloss, high fullness, high hardness, good weather resistance

Construction guidance

The construction site should be well ventilated. If the construction is carried out in a relatively closed place, effective auxiliary facilities, such as industrial fans and fans, should be adopted to strengthen the air circulation in the construction site.

The ambient temperature shall not be less than 5℃, and the surface temperature of the substrate shall be more than 3℃ higher than the dew point temperature

The relative humidity should be less than 80%. If it is continuously cloudy and the relative humidity exceeds 80%, it is recommended to stop construction or use auxiliary ventilation equipment to enhance air circulation and ensure normal dryness.

Do not work outdoors in rain, snow or dew. If the component has been constructed and the paint film is not dry, the method of tarpaulin shielding should be adopted to protect the paint film, or the component will be moved to indoor protection.

3.4 Engine coating solution

Engine supporting system

Waterborne acrylic primer + waterborne acrylic polyurethane topcoat

Product features

The paint film has the characteristics of high hardness, high gloss, high fullness, good wear resistance, excellent water resistance, chemical resistance, good weather resistance, low VOC content of paint. It is suitable for light anticorrosion and protection of auto parts and engines.

Construction guidance

The construction site should be well ventilated. If the construction is carried out in a relatively closed place, effective auxiliary facilities, such as industrial fans and fans, should be adopted to strengthen the air circulation in the construction site.

The ambient temperature shall not be less than 5℃, and the surface temperature of the substrate shall be more than 3℃ higher than the dew point temperature

The relative humidity should be less than 80%. If it is continuously cloudy and the relative humidity exceeds 80%, it is recommended to stop construction or use auxiliary ventilation equipment to enhance air circulation and ensure normal dryness.

Do not work outdoors in rain, snow or dew. If the component has been constructed and the paint film is not dry, the method of tarpaulin shielding should be adopted to protect the paint film, or the component will be moved to indoor protection.